AUTNZ
Features
Dry type autotransformer
Anti-flash varnish finish, offering:
- Protection against corrosive environments
- Increase of electrical isolation
- High compression capacity
- Reduction of noise level
- Increase of product’s lifespan
IP-65 up to 63kVA and IP-54 as from 80kVA (for IP-65 degree consult us) metallic box enclosure painted with polyester resin RAL 7035 (cat. C4 ISO 12994-2)
Safety class I
Includes cable glands, silent-blocks and stainless steel lifting eyebolts from 12,5 kVA
Possibility of tailor-made manufacturing
Downloads
AUTNZ1 » | AUTNZ2 » | AUTNZ3.15 » | AUTNZ5 » | AUTNZ8 » | AUTNZ10 » | AUTNZ12.5 » | AUTNZ16 » | AUTNZ20 » | AUTNZ25 » | AUTNZ31.5 » | AUTNZ40 » | AUTNZ50 » | AUTNZ63 » | AUTNZ80 » | AUTNZ100 » | AUTNZ125 » | AUTNZ160 » | AUTNZ200 » | AUTNZ250 » | AUTNZ315 » | AUTNZ400 » | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Rating | 1 kVA | 2 kVA | 3,15 kVA | 5 kVA | 8 kVA | 10 kVA | 12,5 kVA | 16 kVA | 20 kVA | 25 kVA | 31,5 kVA | 40 kVA | 50 kVA | 63 kVA | 80 kVA | 100 kVA | 125 kVA | 160 kVA | 200 kVA | 250 kVA | 315 kVA | 400 kVA |
Input voltage | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V |
Output voltage | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL | NEUTRAL |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Connection group | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 | ZN0 |
Cover | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) |
Protection degree | IP-65 / IK-10 | IP-65 / IK-10 | IP-65 / IK-10 | IP-65 / IK-10 | IP-65 / IK-10 | IP-65 / IK-10 | IP-65 / IK-10 | IP-65 / IK-10 | IP-65 / IK-10 | IP-65 / IK-10 | IP-65 / IK-10 | IP-65 / IK-10 | IP-65 / IK-10 | IP-65 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 |
Cooling | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF |
Ambient temperature | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC |
Temperature rise | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
Insulation | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
Windings | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC |
Test voltage | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) |
Standards | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE |
Includes | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks |
Weight | 24 kg | 30 kg | 47 kg | 60 kg | 67 kg | 77 kg | 110 kg | 124 kg | 132 kg | 144 kg | 155 kg | 177 kg | 189 kg | 260 kg | 286 kg | 349 kg | 400 kg | 430 kg | 658 kg | 764 kg | 844 kg | 994 kg |
Dimensions (AxBxCxDxE) | 330x284x463x230x200 mm 11Ø | 330x284x463x230x200 mm 11Ø | 510x362x689x320x250 mm 11Ø | 510x362x689x320x250 mm 11Ø | 510x362x689x320x250 mm 11Ø | 510x362x689x320x250 mm 11Ø | 694x413x764x370x350 mm 11Ø | 694x413x764x370x350 mm 11Ø | 694x413x764x370x350 mm 11Ø | 694x413x764x370x350 mm 11Ø | 694x413x764x370x350 mm 11Ø | 694x413x764x370x350 mm 11Ø | 694x413x764x370x350 mm 11Ø | 694x413x764x370x350 mm 11Ø | 970x625x1150x500x426 mm 12Ø | 970x625x1150x500x426 mm 12Ø | 970x625x1150x500x426 mm 12Ø | 970x625x1150x500x426 mm 12Ø | 970x625x1150x500x426 mm 12Ø | 1050x900x1370x714x485 mm 18Ø | 1050x900x1370x714x485 mm 18Ø | 1550x1000x1750x806x684 mm 18Ø |
Quote / Buy |
How to buy?
You can buy online if you are located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden.
Related series
Special fabrications
We build transformers and inductive elements tailored to your needs.
Explain your needs and our engineers will create a solution adapted to your company.