R
Features
Advantages of resin technology:
- Protection against corrosive environments
- Protection against high vibration levels
- Protection against electrodynamic efforts
- Reduction of noise level
- Increase of product’s lifespan
Includes thermal protection against overtemperatures
DIN rail or screw fixing up to R16.
Possibility of tailor-made manufacturing
Technical remarks about the use of line reactors:
- Reduction of the current harmonics generated by the equipment, reducing current consumption and improving power factor
- Reduction of the peak factor of the current wave, increasing equipment’s lifespan
- Attenuation of the microcuts of the feeding voltage produced by the converter, source of the bad functioning of computers, robots and other equipments
Applications
- Single-phase low rating installations where harmonic filtering is required, such as those with non-linear loads, rectifiers, single-phase frequency converters, power supplies, etc.
- Environments with high humidity or corrosion, as well as vibrations and voltage peaks, due to the resin coating.
Downloads
R2.5 » | R4 » | R5 » | R6.3 » | R8 » | R10 » | R12.5 » | R16 » | R20 » | R25 » | R31.5 » | R40 » | R50 » | R63 » | R80 » | R100 » | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Rated current | 2,5 A | 4 A | 5 A | 6,3 A | 8 A | 10 A | 12,5 A | 16 A | 20 A | 25 A | 31,5 A | 40 A | 50 A | 63 A | 80 A | 100 A |
Motor rating | 0,23 kW / 0,31 CV | 0,38 kW / 0,5 CV | 0,46 kW / 0,6 CV | 0,55 kW / 0,75 CV | 0,75 kW / 1 CV | 1,1 kW / 1,5 CV | 1,5 kW / 2 CV | 1,85 kW / 2,5 CV | 2,2 kW / 3 CV | 3 kW / 4 CV | 4 kW / 5,5 CV | 5,5 kW / 7,5 CV | 6,5 kW / 8,7 CV | 7,5 kW / 10 CV | 11 kW / 15 CV | 14 kW / 18,7 CV |
Line voltage | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V |
Reactor | 8,785 mH (50 Hz) | 5,491 mH (50 Hz) | 4,393 mH (50 Hz) | 3,486 mH (50 Hz) | 2,745 mH (50 Hz) | 2,196 mH (50 Hz) | 1,757 mH (50 Hz) | 1,373 mH (50 Hz) | 1,098 mH (50 Hz) | 0,879 mH (50 Hz) | 0,697 mH (50 Hz) | 0,549 mH (50 Hz) | 0,439 mH (50 Hz) | 0,349 mH (50 Hz) | 0,275 mH (50 Hz) | 0,22 mH (50 Hz) |
Voltage drop | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Protection degree | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 |
Thermal protection | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C |
Cooling | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN |
Ambient temperature | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC |
Temperature rise | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC |
Insulation | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
Windings | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC |
Test voltage | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) |
Standards | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE |
Mounting | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws |
Weight | 0,76 kg | 0,78 kg | 0,94 kg | 1,3 kg | 1,3 kg | 1,3 kg | 1,3 kg | 1,8 kg | 2,7 kg | 2,8 kg | 2,9 kg | 5 kg | 5,6 kg | 8,1 kg | 8,3 kg | 10,6 kg |
Dimensions (AxBxCxDxE) | 50x97x84x80x34 mm 6Ø | 50x97x89x80x34 mm 6Ø | 50x97x94x80x34 mm 6Ø | 75x96x95x80x56 mm 6Ø | 75x96x95x80x56 mm 6Ø | 75x96x95x80x56 mm 6Ø | 75x96x95x80x56 mm 6Ø | 75x96x110x80x56 mm 6Ø | 84x102x120x86x65 mm 6Ø | 96x112x126x96x77 mm 6Ø | 96x112x126x96x77 mm 6Ø | 108x122x155x106x89 mm 6Ø | 126x145x167x125x102 mm 6Ø | 126x145x187x125x102 mm 7Ø | 126x145x187x125x102 mm 7Ø | 150x165x200x145x125 mm 7Ø |