RTL
Features
Reactor
Advantages of resin technology:
- Protection against corrosive environments
- Protection against high vibration levels
- Protection against electrodynamic efforts
- Reduction of noise level
- Increase of product's lifespan
Safety class I
Includes thermal protection against overtemperatures
Possibility of tailor-made manufacturing
Technical remarks about the use of line reactors:
- Reduction of the current harmonics generated by the equipment, reducing current consumption and improving power factor
- Reduction of the peak factor of the current wave, increasing equipment's lifespan
- Attenuation of the microcuts of the feeding voltage produced by the converter, source of the bad functioning of computers, robots and other equipments
Downloads
RTL2.5 » | RTL4 » | RTL5 » | RTL6.3 » | RTL8 » | RTL10 » | RTL12.5 » | RTL16 » | RTL20 » | RTL25 » | RTL31.5 » | RTL40 » | RTL50 » | RTL63 » | RTL80 » | RTL100 » | RTL125 » | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Rated current | 2,5 A | 4 A | 5 A | 6,3 A | 8 A | 10 A | 12,5 A | 16 A | 20 A | 25 A | 31,5 A | 40 A | 50 A | 63 A | 80 A | 100 A | 125 A |
Motor rating | 0,75 kW / 1 CV | 1,1 kW / 1,5 CV | 1,5 kW / 2 CV | 2,2 kW / 3 CV | 3 kW / 4 CV | 4 kW / 5,5 CV | 5,5 kW / 7,5 CV | 6,5 kW / 8,7 CV | 7,5 kW / 10 CV | 11 kW / 15 CV | 15 kW / 20 CV | 18,5 kW / 25 CV | 22 kW / 30 CV | 30 kW / 40 ºCV | 37 kW / 50 CV | 45 kW / 60 CV | 55 kW / 75 CV |
Line voltage | 380 – 460 V | 380 – 460 V | 380 – 460 V | 380 – 460 V | 380 – 460 V | 380 – 460 V | 380 – 460 V | 380 – 460 V | 380 – 460 V | 380 – 460 V | 380 – 460 V | 380 – 460 V | 380 – 460 V | 380 – 460 V | 380 – 460 V | 380 – 460 V | 380 – 460 V |
Reactor | 11,762 mH (50 Hz) | 7,351 mH (50 Hz) | 5,881 mH (50 Hz) | 4,667 mH (50 Hz) | 3,676 mH (50 Hz) | 2,941 mH (50 Hz) | 2,352 mH (50 Hz) | 1,838 mH (50 Hz) | 1,470 mH (50 Hz) | 1,176 mH (50 Hz) | 0,933 mH (50 Hz) | 0,735 mH (50 Hz) | 0,588 mH (50 Hz) | 0,467 mH (50 Hz) | 0,368 mH (50 Hz) | 0,294 mH (50 Hz) | 0,235 mH (50 Hz) |
Voltage drop | 4% (50 Hz) | 4% (50 Hz) | 4% (50 Hz) | 4% (50 Hz) | 4% (50 Hz) | 4% (50 Hz) | 4% (50 Hz) | 4% (50 Hz) | 4% (50 Hz) | 4% (50 Hz) | 4% (50 Hz) | 4% (50 Hz) | 4% (50 Hz) | 4% (50 Hz) | 4% (50 Hz) | 4% (50 Hz) | 4% (50 Hz) |
Thermal overload factor | 0,05 | 0,05 | 0,05 | 0,05 | 0,05 | 0,05 | 0,05 | 0,05 | 0,05 | 0,05 | 0,05 | 0,05 | 0,05 | 0,05 | 0,05 | 0,05 | 0,05 |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Protection degree | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 |
Cooling | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN |
Ambient temperature | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC |
Temperature rise | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC |
Insulation | Clase H – 180 ºC | Clase H – 180 ºC | Clase H – 180 ºC | Clase H – 180 ºC | Clase H – 180 ºC | Clase H – 180 ºC | Clase H – 180 ºC | Clase H – 180 ºC | Clase H – 180 ºC | Clase H – 180 ºC | Clase H – 180 ºC | Clase H – 180 ºC | Clase H – 180 ºC | Clase H – 180 ºC | Clase H – 180 ºC | Clase H – 180 ºC | Clase H – 180 ºC |
Windings | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC |
Test voltage | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) |
Standards | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE |
Mounting | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws |
Includes | Bimetal thermal protection | Bimetal thermal protection | Bimetal thermal protection | Bimetal thermal protection | Bimetal thermal protection | Bimetal thermal protection | Bimetal thermal protection | Bimetal thermal protection | Bimetal thermal protection | Bimetal thermal protection | Bimetal thermal protection | Bimetal thermal protection | Bimetal thermal protection | Bimetal thermal protection | Bimetal thermal protection | Bimetal thermal protection | Bimetal thermal protection |
Weight | 1,5 kg | 1,7 kg | 2 kg | 2,5 kg | 2,7 kg | 3,4 kg | 3,9 kg | 5,3 kg | 6 kg | 7,5 kg | 9,7 kg | 10,2 kg | 13,9 kg | 16,7 kg | 20,1 kg | 24,5 kg | 30,3 kg |
Dimensions (AxBxCxDxE) | 135x145x108x125x102 mm 7Ø | 135x145x108x125x102 mm 7Ø | 135x145x108x125x102 mm 7Ø | 135x145x108x125x102 mm 7Ø | 135x145x108x125x102 mm 7Ø | 170x165x138x145x125 mm 7 | 170x165x138x145x125 mm 7Ø | 170x165x138x145x125 mm 7Ø | 210x198x185x178x173 mm 7Ø | 210x198x185x178x173 mm 7Ø | 210x198x185x178x173 mm 7Ø | 210x198x185x178x173 mm 7Ø | 280x190x205x80x250 mm 9Ø | 280x190x205x100x250 mm 9Ø | 280x190x205x115x250 mm 9Ø | 280x220x205x110x250 mm 9 | 340x220x255x106x310 mm 9Ø |
Quote / Buy |
How to buy?
You can buy online if you are located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden.
Special fabrications
We build transformers and inductive elements tailored to your needs.
Explain your needs and our engineers will create a solution adapted to your company.