Features

Dry type transformer

All transformers are dipped in anti-flash varnish for increased insulation and compactness.

Reduces long-term operating costs.

Low temperature rise.

Longer life than standard transformers.

Prepared for higher ambient temperatures.

Low connection peak.

Lower noise level.

Safety class I.

Includes lifting eyebolts.

Metalic box IP-54/65 enclosure painted with Polyester resin RAL 7035 (cat. C4 ISO 12994-2).

Possibility of tailor-made manufacturing.

Applications

  • Circuit isolation, with the possibility of increasing or reducing the voltage.
  • Reducing voltage drops in installations with long cable lengths. With the installation of a step-up transformer and a step-down transformer.
  • In installations with a certain level of electrical noise, the TTG series helps to improve the electrical network quality in secondary.
  • Changing the neutral system of an installation
  • In installations where energy savings is critical, or where a lower connection peak is required such as renewable energy plants or high energy efficiency installations.

Available accessories

  • Protections in primary and secondary.
  • One, two and up to 3 electrostatic screens.
  • Class II
  • Wheels.
  • PT100, PTC or Bimetallic probes.
  • Painting C5.
  • Different RAL.
  • Temperature control unit
  • Anti condensation system
  • Different IP up to IP-65

CE certificate

TTGZ10 » TTGZ12.5 » TTGZ16 » TTGZ20 » TTGZ25 » TTGZ31.5 » TTGZ40 » TTGZ50 » TTGZ63 » TTGZ80 » TTGZ100 » TTGZ125 » TTGZ160 » TTGZ200 » TTGZ250 » TTGZ315 » TTGZ400 »
Rating 10 kVA 12,5 kVA 16 kVA 20 kVA 25 kVA 31,5 kVA 40 kVA 50 kVA 63 kVA 80 kVA 100 kVA 125 kVA 160 kVA 200 kVA 250 kVA 315 kVA 315 kVA
Input voltage 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V
Output voltage 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V
Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Connection group Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0
Cover Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) Metal enclosure RAL 7035 (cat. C4 ISO 12994-2)
Protection degree IP-65 / IK-10 IP-65 / IK-10 IP-65 / IK-10 IP-65 / IK-10 IP-65 / IK-10 IP-65 / IK-10 IP-65 / IK-10 IP-54 / IK-10 IP-54 / IK-10 IP-54 / IK-10 IP-54 / IK-10 IP-54 / IK-10 IP-54 / IK-10 IP-54 / IK-10 IP-54 / IK-10 IP-54 / IK-10 IP-54 / IK-10
Cooling ANAN ANAN ANAN ANAN ANAN ANAN ANAN ANAF ANAF ANAF ANAF ANAF ANAF ANAF ANAF ANAF ANAF
Ambient temperature 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC
Temperature rise Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC
Insulation Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC
Windings Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC
Inrush current < 8In < 8In < 8In < 8In < 8In < 8In < 8In < 8In < 8In < 8In < 8In < 8In < 8In < 8In < 8In < 8In < 8In
Voltage drop < 2 % < 2 % < 2 % < 2 % < 2 % < 2 % < 2 % < 2 % < 2 % < 2 % < 2 % < 2 % < 2 % < 2 % < 2 % < 2 % < 2 %
Efficiency (%) 97,7 98 98 98 98,1 98,2 98,3 97,8 98 98,1 98,3 98,2 98,3 98,5 98,7 98,8 98,8
Noise level (dB) < 45 < 45 < 45 < 45 < 45 < 45 < 45 < 55 < 55 < 55 < 55 < 55 < 55 < 55 < 65 < 65 < 65
Test voltage 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz)
Standards IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE
Weight 130 kg 153 kg 192 kg 206 kg 238 kg 252 kg 299 kg 343 kg 386 kg 434 kg 627 kg 663 kg 913 kg 1027 kg 1187 kg 1282 kg 1395 kg
Dimensions (AxBxCxDxE) 694x413x764x370x350 mm 11Ø 694x413x764x370x350 mm 11Ø 694x413x764x370x350 mm 11Ø 694x413x764x370x350 mm 11Ø 694x413x764x370x350 mm 11Ø 694x413x764x370x350 mm 11Ø 694x413x764x370x350 mm 11Ø 970x625x1150x500x426 mm 12Ø 970x625x1150x500x426 mm 12Ø 970x625x1150x500x426 mm 12Ø 970x625x1150x500x426 mm 12Ø 1050x900x1370x714x485 mm 18Ø 1050x900x1370x714x485 mm 18Ø 1050x900x1370x714x485 mm 18Ø 1550x1000x1750x806x684 mm 18Ø 1550x1000x1750x806x684 mm 18Ø 1550x1000x1750x806x684 mm 18Ø
Quote / Buy Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote
How to buy?

You can buy online if you are located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden.

Related series

TTGX THREE-PHASE ECOLOGICAL ISOLATION TRANSFORMERS
TTGX
Rating
From 10 kVA to 400 kVA
Input voltage
400 V
Output voltage
400 V
Protection degree
IP-00
TTGW THREE-PHASE ECOLOGICAL ISOLATION TRANSFORMERS
TTGW
Rating
From 10 kVA to 400 kVA
Input voltage
400 V
Output voltage
400 V
Protection degree
IP-23/IK-08

Special fabrications

We build transformers and inductive elements tailored to your needs.

Explain your needs and our engineers will create a solution adapted to your company.