Features

Dry type transformer

Anti-flash varnish finish, offering:

  • Protection against corrosive environments
  • Increase of electrical isolation
  • High compression capacity
  • Reduction of noise level
  • Increase of product's lifespan

Safety class I

Neutral sized for 2 x In

K factor = 20

Includes lifting eyebolts

Possibility of tailor-made manufacturing

Downloads

TTFK2X10 » TTFK2X12.5 » TTFK2X16 » TTFK2X20 » TTFK2X25 » TTFK2X31.5 » TTFK2X40 » TTFK2X50 » TTFK2X63 » TTFK2X80 » TTFK2X100 » TTFK2X125 » TTFK2X160 » TTFK2X200 » TTFK2X250 » TTFK2X315 » TTFK2X400 »
Rating 10 kVA 12,5 kVA 16 kVA 20 kVA 25 kVA 31,5 kVA 40 kVA 50 kVA 63 kVA 80 kVA 100 kVA 125 kVA 160 kVA 200 kVA 250 kVA 315 kVA 400 kVA
Input voltage 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V
Output voltage 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V
Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
k Factor 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
THDI (<=) 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9
Connection group Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11
Protection degree IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00
Cooling AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN
Ambient temperature 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC
Temperature rise Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC
Insulation Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC
Windings Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC
Test voltage 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz)
Standards IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE
Weight 96 kg 109 kg 120 kg 159 kg 182 kg 221 kg 254 kg 347 kg 405 kg 441 kg 544 kg 660 kg 758 kg 966 kg 1176 kg 1801 kg 2198 kg
Dimensions (AxBxCxDxE) 480x250x480x144x400 mm 11Ø 480x260x480x154x400 mm 11Ø 480x270x480x164x400 mm 11Ø 480x310x480x204x400 mm 11Ø 670x290x580x150x426 mm 13Ø 670x310x580x170x426 mm 13Ø 670x330x580x190x426 mm 13Ø 785x550x880x460x472 mm 17Ø 785x550x880x460x472 mm 17Ø 785x550x880x460x472 mm 17Ø 785x550x880x460x472 mm 17Ø 785x550x880x460x472 mm 17Ø 1016x550x1080x460x690 mm 17Ø 1070x550x1220x460x690 mm 17Ø 1070x550x1220x460x690 mm 17Ø 1300x550x1350x460x800 mm 17Ø 1300x550x1350x460x800 mm 17Ø
Quote / Buy Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote
How to buy?

You can buy online if you are located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden.

Related series

TTFKX THREE-PHASE ISOLATION TRANSFORMERS FOR INSTALLATIONS WITH A 30% HARMONICS RATE
TTFKX
Rating
From 10 kVA to 500 kVA
Input voltage
400 V
Output voltage
400 V
Protection degree
IP-00
TTFKW THREE-PHASE ISOLATION TRANSFORMERS FOR INSTALLATIONS WITH A 30% HARMONICS RATE
TTFKW
Rating
From 10 kVA to 500 kVA
Input voltage
400 V
Output voltage
From 400 V to 400 V
Protection degree
IP-23 / IK-08
TTFKZ THREE-PHASE ISOLATION TRANSFORMERS FOR INSTALLATIONS WITH A 30% HARMONICS RATE
TTFKZ
Rating
From 10 kVA to 500 kVA
Input voltage
400 V
Output voltage
400 V
Protection degree
From IP-65 / IK-10 to IP-54 / IK-10
TTFK2W THREE-PHASE ISOLATION TRANSFORMERS FOR INSTALLATIONS WITH A 60% HARMONICS RATE
TTFK2W
Rating
From 10 kVA to 400 kVA
Input voltage
400 V
Output voltage
400 V
Protection degree
IP-23 / IK-08
TTFK2Z THREE-PHASE ISOLATION TRANSFORMERS FOR INSTALLATIONS WITH A 60% HARMONICS RATE
TTFK2Z
Rating
From 10 kVA to 315 kVA
Input voltage
400 V
Output voltage
400 V
Protection degree
From IP-65 / IK-10 to IP-54 / IK-10

Special fabrications

We build transformers and inductive elements tailored to your needs.

Explain your needs and our engineers will create a solution adapted to your company.