TTFK2Z
Features
Dry type transformer
Anti-flash varnish finish, offering:
- Protection against corrosive environments
- Increase of electrical isolation
- High compression capacity
- Reduction of noise level
- Increase of product’s lifespan
IP-65 up to 16 kVA and IP-54 as from 20 kVA (for IP-65 degree consult us) metallic box enclosure painted with polyester resin RAL 7035 (cat. C4 ISO 12994-2)
Safety class I
Neutral sized for 2 x In
Factor K = 20
Includes cable glands, silent-blocks and stainless steel lifting eyebolts
Possibility of tailor-made manufacturing
Downloads
TTFK2Z10 » | TTFK2Z12.5 » | TTFK2Z16 » | TTFK2Z20 » | TTFK2Z25 » | TTFK2Z31.5 » | TTFK2Z40 » | TTFK2Z50 » | TTFK2Z63 » | TTFK2Z80 » | TTFK2Z100 » | TTFK2Z125 » | TTFK2Z160 » | TTFK2Z200 » | TTFK2Z250 » | TTFK2Z315 » | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Rating | 10 kVA | 12,5 kVA | 16 kVA | 20 kVA | 25 kVA | 31,5 kVA | 40 kVA | 50 kVA | 63 kVA | 80 kVA | 100 kVA | 125 kVA | 160 kVA | 200 kVA | 250 kVA | 315 kVA |
Input voltage | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V |
Output voltage | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
k Factor | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
Cover | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) |
THDI (<=) | 0,9 | 0,9 | 0,9 | 0,9 | 0,9 | 0,9 | 0,9 | 0,9 | 0,9 | 0,9 | 0,9 | 0,9 | 0,9 | 0,9 | 0,9 | 0,9 |
Connection group | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 |
Protection degree | IP-65 / IK-10 | IP-65 / IK-10 | IP-65 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 | IP-54 / IK-10 |
Cooling | ANAN | ANAN | ANAN | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF |
Ambient temperature | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC |
Temperature rise | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
Insulation | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
Windings | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC |
Test voltage | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) |
Standards | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE |
Weight | 149 kg | 160 kg | 199 kg | 247 kg | 286 kg | 319 kg | 476 kg | 534 kg | 570 kg | 673 kg | 815 kg | 926 kg | 1152 kg | 1362 kg | 2001 kg | 2398 kg |
Dimensions (AxBxCxDxE) | 738x417x760x370x350 mm 11Ø | 738x417x760x370x350 mm 11Ø | 738x417x760x370x350 mm 11Ø | 890x625x1148x500x426 mm 12Ø | 970x625x1150x500x426 mm 12Ø | 970x625x1150x500x426 mm 12Ø | 970x625x1150x500x426 mm 12Ø | 970x625x1150x500x426 mm 12Ø | 970x625x1150x500x426 mm 12Ø | 1050x900x1370x714x485 mm 18Ø | 1050x900x1370x714x485 mm 18Ø | 1050x900x1370x714x485 mm 18Ø | 1550x1000x1750x806x684 mm 18Ø | 1550x1000x1750x806x684 mm 18Ø | 1550x1000x1750x806x684 mm 18Ø | 1950x1100x1800x900x790 mm 20Ø |
Quote / Buy |
How to buy?
You can buy online if you are located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden.
Related series
Special fabrications
We build transformers and inductive elements tailored to your needs.