Features
Dry type resin cast transformer
Advantages of resin technology:
- Protection against corrosive environments
- Protection against high vibration levels
- Protection against electrodynamic efforts
- Reduction of noise level
- Increase of product’s lifespan
Safety class II.
Includes LED functioning indicator
Input connector: Schuko with cable 2 m
Output socket and plugs: CETAC (160 VA 1 socket | 250 VA 2 sockets| 400 VA and 630 VA 4 sockets).
Short circuit protection by temporised primary fuse
Possibility of custom-made manufacturing
Applications
-
The TP transformers are portable transformers designed to feed low voltage single phase loads in limited acces areas, or areas where there is no electricity.
-
Furthermore, the cast resin format of the TP is an optimal solution for areas and applications that must withstand corrosive and adverse Environments.
-
In outdoor installations with adverse weather conditions, the high protection degree of the TP transformers: IP-54, also makes this transformer, a really suitable solution.
Available accessories
- Different sockets / plugs.
- Neoprene protected cables.
Downloads
TPA160 » | TPA250 » | TPB250 » | TPA400 » | TPB160 » | TPB400 » | TPA630 » | TPB630 » | |
---|---|---|---|---|---|---|---|---|
Rating | 160 VA | 250 VA | 250 VA | 400 VA | 160 VA | 400 VA | 630 VA | 630 VA |
Input voltage | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V |
Output voltage | 12 V | 12 V | 24 V | 12 V | 24 V | 24 V | 12 V | 24 V |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Protection degree | IP-54 | IP-54 | IP-54 | IP-54 | IP-54 | IP-54 | IP-54 | IP-54 |
Cooling | AN | AN | AN | AN | AN | AN | AN | AN |
Ambient temperature | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC |
Temperature rise | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC |
Insulation | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
Windings | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC |
Test voltage | 3,5 kV (1 min, 50 Hz) | 3,5 kV (1 min, 50 Hz) | 3,5 kV (1 min, 50 Hz) | 3,5 kV (1 min, 50 Hz) | 3,5 kV (1 min, 50 Hz) | 3,5 kV (1 min, 50 Hz) | 3,5 kV (1 min, 50 Hz) | 3,5 kV (1 min, 50 Hz) |
Standards | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE |
Mounting | – | – | – | – | – | – | – | – |
Weight | 6,8 kg | 10 kg | 10 kg | 16,1 kg | 6,8 kg | 16,1 kg | 20,5 kg | 20,5 kg |
Dimensions (AxBxCxDxE) | 210x170x160 mm | 215x200x180 mm | 215x210x180 mm | 245x265x235 mm | 210x200x160 mm | 245x300x235 mm | 245x265x235 mm | 245x300x235 mm |
Quote / Buy |
How to buy?
You can buy online if you are located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden.
Special fabrications
We build transformers and inductive elements tailored to your needs.
Explain your needs and our engineers will create a solution adapted to your company.